Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Nutr ; 63(1): 185-193, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37794214

RESUMEN

PURPOSE: Relationships between body weight, urine color (Uc), and thirst level (WUT) have been proposed as a simple and inexpensive self-assessment method to predict dehydration. This study aimed to determine if this method also allowed us to accurately identify a low vs. high urine concentration in (tactical) athletes. METHODS: A total of n = 19 Army Reserve Officer Training Corps cadets and club sports athletes (22.7 ± 3.8 years old, of which 13 male) were included in the analysis, providing morning body weight, thirst sensation, and Uc for five consecutive days. Each item received a score 0 or 1, resulting in a WUT score ranging from 0 (likely hydrated) to 3 (very likely dehydrated). WUT model and individual item outcomes were then compared with a ≥ 1.020 urine specific gravity (USG) cut-off indicating a high urine concentration, using descriptive comparisons, generalized linear mixed models, and logistic regression (to calculate the area under the curve (AUC)). RESULTS: WUT score was not significantly predictive of urine concentration, z = 1.59, p = 0.11. The AUC ranged from 0.54 to 0.77 for test days, suggesting a fair AUC on most days. Only Uc was significantly related to urine concentration, z = 2.49, p = 0.01. The accuracy of the WUT model for correctly classifying urine samples with a high concentration was 68% vs. 51% of samples with a low concentration, resulting in an average accuracy of 61%. CONCLUSION: This study shows that WUT scores were not predictive of urine concentration, and the method did not substantially outperform the accuracy of Uc scoring alone.


Asunto(s)
Deshidratación , Autoevaluación (Psicología) , Humanos , Masculino , Adolescente , Adulto Joven , Adulto , Deshidratación/diagnóstico , Deshidratación/orina , Urinálisis/métodos , Peso Corporal , Atletas
2.
Drug Test Anal ; 15(10): 1257-1269, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36876729

RESUMEN

Encouraging adult smokers who are uninterested or unwilling to quit, and would otherwise continue to smoke, to transition to potentially less harmful nicotine products such as electronic nicotine delivery systems (ENDS) may positively impact population health. However, counterbalancing this benefit is the societal concern that ENDS may be used by never smokers and youth and serve as a 'gateway' into cigarette smoking. Data were analysed from two independent surveys of the prevalence and perceptions of myblu ENDS use in the United States. Total sample size was 22,232 young adults and 23,264 adults. Being curious to use myblu was 1.6-2.0 times more likely in young adult current smokers than young adult never smokers. This likelihood was 2.8 times greater for adult current smokers compared with adult never smokers in the perceptions survey, while in the prevalence survey, there was no difference between adult current and never smokers. Intentions to use myblu were significantly greater in young adult current smokers compared with young adult never smokers in both surveys and in adults in the prevalence survey. In all surveys and age cohorts, 124 of 45,496 participants (0.1% of the total survey population) reported first using myblu prior to smoking cigarettes and went on to become established smokers. Curiosity and intentions to use myblu were generally higher in current smokers compared with never smokers. There was minimal evidence to suggest the existence of a 'gateway' effect to established cigarette smoking among never-smoking myblu users.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Cese del Hábito de Fumar , Adolescente , Adulto Joven , Humanos , Estados Unidos , Intención , Estudios Transversales , Conducta Exploratoria , Encuestas y Cuestionarios
3.
Drug Test Anal ; 15(10): 1270-1280, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35712897

RESUMEN

BACKGROUND: Greater nicotine delivery is associated with higher nicotine concentrations in electronic nicotine delivery system (ENDS) liquids. However, there is a current debate as to whether this leads to increased dependence and mitigates ENDS public health potential. METHODS: Self-reported dependence among users of myblu ENDS containing different nicotine concentrations was examined with data from a multiwave cross-sectional survey of US young adults and adults. Questions examined responses related to dependence measures and participants' most often used myblu ENDS nicotine concentration (low: 0%, 1% and 1.2%; medium: 2%, 2.4% and 2.5%; or high: 3.6% and 4%). RESULTS: A global general linear model using nicotine concentration, age and days myblu that was used in the past 30 revealed a significant difference in PROMIS scores among nicotine concentration groups (F = 4.07, p = 0.02). However, pairwise comparisons to examine which specific groups differed significantly from others showed no significant differences. Logistic regression demonstrated that strong past 30-day cravings to use myblu among participants using high or medium nicotine concentrations were not significantly different from those using a low concentration (ORs 0.66 [0.42, 1.03], p = 0.07 and 0.95 [0.49, 1.82], p = 0.98, respectively). Time to daily first use for high or medium nicotine concentration users was not significantly different from those using a low concentration (ORs 0.89 [0.70, 1.14], p = 0.35 and 0.84 [0.57, 1.25], p = 0.40, respectively). CONCLUSIONS: Use of myblu ENDS with different nicotine concentrations is not associated with differing levels of dependence. Our findings contradict the notion that high ENDS e-liquid nicotine levels generate increased dependence.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Tabaquismo , Adulto Joven , Humanos , Nicotina , Tabaquismo/diagnóstico , Autoinforme , Estudios Transversales
4.
Harm Reduct J ; 19(1): 57, 2022 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-35655314

RESUMEN

BACKGROUND: Nicotine pharmacokinetic assessments of electronic nicotine delivery systems (ENDS) are crucial to understand their ability to provide an alternative to cigarette smoking. Subjective effects data also strongly contribute to this understanding. The BIDI® Stick is a disposable ENDS product which contains 59 mg/ml nicotine benzoate salt and various flavours. METHODS: In this study, we assessed nicotine pharmacokinetics and subjective effects of 6 flavour variants of BIDI® Stick ENDS in adult smokers, compared to cigarettes and a comparator ENDS product. During each of eight study visits, 18 volunteer smoker subjects randomly used one of either their usual brand (UB) of cigarette, a BIDI® Stick ENDS, or a comparator ENDS (JUUL 59 mg/ml nicotine with Virginia Tobacco flavour), during both controlled (10 puffs, 30 s apart) and ad libitum (60 min) puffing sessions. Blood samples were collected at various time points and subjective effects questionnaires were administered. RESULTS: Mean [SD] plasma nicotine Cmax 0-120 was not significantly different between BIDI® Stick ENDS with any flavour (range 15.3 [9.90] ng/ml for BIDI® Stick Winter to 17.6 [9.00] ng/ml for BIDI® Stick Classic) and UB cigarettes (16.2 [9.17] ng/ml). Mean [SD] AUC0-120 (range 569.7 [327.29] to 628.6 [408.99]  min*ng/ml for BIDI® Stick ENDS and 747.1 [325.48]  min*ng/ml for UB cigarettes) and median Tmax 0-120 (range 5-7 min for all BIDI® Stick ENDS and UB cigarettes) values were also not significantly different between BIDI® Stick ENDS and UB cigarettes, while subjective effects measures were also similar between BIDI® Stick ENDS and UB cigarettes. Mean [SD] plasma nicotine Cmax 0-120, AUC0-120, and median Tmax 0-120 were 6.8 [4.13] ng/ml, 243.6 [179.04] min*ng/ml, and 5 min, respectively, for JUUL ENDS. These values were significantly different compared with those for all BIDI® Stick ENDS and UB cigarettes for both Cmax 0-120 and AUC0-120 but not for Tmax 0-120. CONCLUSIONS: BIDI® Stick ENDS delivered nicotine to users comparably to their UB combustible cigarette and higher than JUUL ENDS, and also elicited similar subjective effects such as satisfaction and relief. Thus, the BIDI® Stick ENDS may be a satisfying alternative to cigarettes among current smokers and may support their transitioning away from cigarette smoking. TRIAL REGISTRATION: ClinicalTrials.gov (identifier number NCT05072925).


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Adulto , Aromatizantes , Humanos , Nicotina/farmacología , Fumadores , Encuestas y Cuestionarios
5.
JMIR Med Inform ; 9(5): e24721, 2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-33973862

RESUMEN

BACKGROUND: Though shock wave lithotripsy (SWL) has developed to be one of the most common treatment approaches for nephrolithiasis in recent decades, its treatment planning is often a trial-and-error process based on physicians' subjective judgement. Physicians' inexperience with this modality can lead to low-quality treatment and unnecessary risks to patients. OBJECTIVE: To improve the quality and consistency of shock wave lithotripsy treatment, we aimed to develop a deep learning model for generating the next treatment step by previous steps and preoperative patient characteristics and to produce personalized SWL treatment plans in a step-by-step protocol based on the deep learning model. METHODS: We developed a deep learning model to generate the optimal power level, shock rate, and number of shocks in the next step, given previous treatment steps encoded by long short-term memory neural networks and preoperative patient characteristics. We constructed a next-step data set (N=8583) from top practices of renal SWL treatments recorded in the International Stone Registry. Then, we trained the deep learning model and baseline models (linear regression, logistic regression, random forest, and support vector machine) with 90% of the samples and validated them with the remaining samples. RESULTS: The deep learning models for generating the next treatment steps outperformed the baseline models (accuracy = 98.8%, F1 = 98.0% for power levels; accuracy = 98.1%, F1 = 96.0% for shock rates; root mean squared error = 207, mean absolute error = 121 for numbers of shocks). The hypothesis testing showed no significant difference between steps generated by our model and the top practices (P=.480 for power levels; P=.782 for shock rates; P=.727 for numbers of shocks). CONCLUSIONS: The high performance of our deep learning approach shows its treatment planning capability on par with top physicians. To the best of our knowledge, our framework is the first effort to implement automated planning of SWL treatment via deep learning. It is a promising technique in assisting treatment planning and physician training at low cost.

6.
Eval Health Prof ; 44(4): 428-435, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-32027175

RESUMEN

It is often not stated or quantified how well measured proxy variables account for the variance in latent constructs they are intended to represent. A sensitivity analysis was run using data from the Survey of Health, Ageing and Retirement in Europe to estimate models varying in the degree to which proxy variables represent intended constructs. Results showed that parameter estimates differ substantially across different levels of variable representation. When variables are used with poor construct validity, an insufficient amount of variance is removed from the observed spurious relationship between design variable and outcome. The findings from this methodological demonstration underscore the importance of selecting proxy variables that accurately represent the underlying construct for which control is intended.


Asunto(s)
Encuestas y Cuestionarios , Humanos
7.
Am J Health Behav ; 36(1): 3-11, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22251778

RESUMEN

OBJECTIVES: To assess the relationship between the mode of entry into a quitline service and subsequent tobacco use treatment outcomes. METHODS: A retrospective study using logistic regression analysis of 11,040 Arizona Smokers' Helpline (ASHLine) clients was conducted to determine whether self- or medical referrals were related to 7- and 30-day point prevalence tobacco treatment outcomes at 7 months postquit. RESULTS: Smokers referred to the ASHLine by a health care provider were more likely to quit smoking than were those who self-referred. CONCLUSIONS: Mode of entry into a quitline service for smoking cessation is related to treatment outcomes. Reasons for this outcome are uncertain and require additional research.


Asunto(s)
Líneas Directas/estadística & datos numéricos , Aceptación de la Atención de Salud/estadística & datos numéricos , Derivación y Consulta/estadística & datos numéricos , Cese del Hábito de Fumar/estadística & datos numéricos , Arizona , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cese del Hábito de Fumar/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...